other
Products

Mining Explosion-Proof and Intrinsically Safe Vacuum Feeder Switch

 Mining explosion-proof and intrinsically safe vacuum feeder switch.Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to 500A(630A) three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
  • Brand:

    WANTAI
  • Item NO.:

    KJZ-500,630
  • Order(MOQ):

    1
  • Payment:

    T/T, L/C, etc.
  • Market Price:

    2000
  • Price:

    $1650/Set
  • Price Range:

    5 - 10
  • Product Origin:

    China
  • Color:

    Optional
  • Shipping Port:

    China port
  • Lead Time:

    30 days
  • Weight:

    346000
Mining explosion-proof vacuum feeder switch

Application
Mining explosion-proof and intrinsically safe vacuum feeder switch.Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to 500A(630A) three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
   The protection system uses high-performance microprocessors and large-capacity new chips for dual-chip work, coupled with high-precision data processing and advanced protection algorithms, with high protection accuracy and fast response speed. Can complete overload, short circuit (divided into phase sensitive protection and current amplitude protection), leakage lockout, leakage protection, selective leakage protection, undervoltage, overvoltage, three-phase imbalance, gas lockout, wind power lockout, power metering and other protection functions, and have communication networking functions.It can also customize the function of live indication, communication networking and power-off locking to the manufacturer.


Characteristics
With Chinese character LCD and menu type human-computer interface, the operation is intuitive and simple. The current time, three-phase current and grid voltage, active power, insulation resistance, main / opening switch, operation status (closing / opening),, wind power locking and fault information are displayed in real time during operation;
The parameters of various protection functions can be adjusted through menu selection, with wide application range and high protection accuracy;
It has the function of "memory". The parameters of each protection function adjusted each time are memorized and saved. The parameters set last time are automatically extracted when the system is powered on or reset. Moreover, the protector can also memorize the fault information, which can be displayed through the menu, which is convenient for maintenance;
The function of setting value adjustment, protection test and information inquiry can be conveniently carried out through the button on the door;
The data communication interface can be selected to connect with the monitoring system, and RS485 or domestic leading power line carrier communication interface can be equipped according to the user's needs;

The protector adopts modular structure, optimized software and hardware anti-interference processing, and has friendly man-machine interface, which makes the installation, use and maintenance easier and the service life is greatly increased.


Main technical parameters
Rated voltage:660V,1140V;
Protective measurement unit operating voltage:AC65~260V;
Normal operating voltage range for protection measuring units:75~110%;
Rated operating frequency:50Hz;
Rated Current:500,630A;
Limit Break Current:9KA;
Short circuit protection action time:<100ms;
Electrical life :3000 times;
Mechanical life :15000 times;
Circuit breaker contact technical parameters:
Open contact distance:3±0.5 mm;
Overstroke:  1.5±0.5 mm ;

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
Related Products
Intrinsically Safe Vacuum Feed Switch
Mine Use Intrinsically Safe Vacuum Feed Switch
Application: Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to800, 1000A three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
Explosion Proof Vacuum Feed Switch
Mine Use Explosion Proof Vacuum Feed Switch
Application: Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to800, 1000A three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
Explosion Proof Intrinsically Safe Feed Switch Price
Mine Use Explosion Proof Intrinsically Safe Feed Switch
Application: Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to800, 1000A three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
Mine Explosion-Proof Equipment
Coal Mine Explosion-Proof and Intrinsically Safe Vacuum Feeder Switch
KJZ-500,630/1140(660) Mining explosion-proof and intrinsically safe vacuum feeder switch.Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to 500A(630A) three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
Intrinsically Safe Vacuum Feed Switch
Mine Use Intrinsically Safe Vacuum Feed Switch For Coal Mining
Application: Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to800, 1000A three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
Mining high-voltage vacuum electromagnetic starter
Mine Explosion-Proof and Intrinsically Safe Multi Circuit High Voltage Vacuum Electromagnetic Combination Switch
Mining explosion-proof and intrinsically safe type multi-loop high-voltage vacuum electromagnetic starter is suitable for coal mine AC 3300V, frequency 50Hz, three-phase neutral point unearthed power supply system, local or remote control of three-phase asynchronous electric drive, to realize the centralized control of shearer, scraper conveyor, crusher, transfer machine, pumping station and other equipment in comprehensive mechanized coal mining face.
Coal Mine Use Belt Conveyor Protection Device
Integrated protection device for belt conveyor
Application:It is suitable for the dangerous environment of gas and coal dust explosion. Used for electrical control, monitoring and comprehensive protection of belt conveyor and other equipments in coal mine.
Ring-network Cabinet
Fully Sealed and Fully Insulated Gas-filled Ring-network Cabinet
Full-sealed and fully insulated gas-filled ring-network cabinet (hereinafter referred to as "gas-filled cabinet") is a new generation of high-voltage switchgear, which has all the functions of 10KV high-voltage switchgear.
We are committed to providing safe, energy-saving, efficient products and system solutions for intelligent mines.

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

whatsapp