other
Products

Mine Use Intrinsically Safe Vacuum Feed Switch

Application: Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to800, 1000A three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
  • Brand:

    WANTAI
  • Item NO.:

    KBZ88-4001140(660)SD
  • Order(MOQ):

    1
  • Payment:

    30% in advance and the rest before delivery
  • Market Price:

    3000
  • Price:

    $3000/Set
  • Price Range:

    5 - 1000
  • Product Origin:

    China
  • Color:

    Can be customized
  • Shipping Port:

    Shanghai port
  • Lead Time:

    25 working days

Mine Explosion Proof Vacuum Feed Switch

Characteristics

1. With Chinese character LCD and menu type human-computer interface, the operation is intuitive and simple. The current time, three-phase current and grid voltage, active power, insulation resistance, main / opening switch, operation status (closing / opening),, wind power locking and fault information are displayed in real time during operation;

2. The parameters of various protection functions can be adjusted through menu selection, with wide application range and high protection accuracy;

3. It has the function of "memory". The parameters of each protection function adjusted each time are memorized and saved. The parameters set last time are automatically extracted when the system is powered on or reset. Moreover, the protector can also memorize the fault information, which can be displayed through the menu, which is convenient for maintenance;

4. The function of setting value adjustment, protection test and information inquiry can be conveniently carried out through the button on the door;

5. The data communication interface can be selected to connect with the monitoring system, and RS485 or domestic leading power line carrier communication interface can be equipped according to the user's needs;

6. The protector adopts modular structure, optimized software and hardware anti-interference processing, and has friendly man-machine interface, which makes the installation, use and maintenance easier and the service life is greatly increased.

 

Main technical parameters

1. Rated voltage:660V,1140V;

2. Protective measurement unit operating voltage:AC65~260V;

3. Normal operating voltage range for protection measuring units:75~110%;

4. Rated operating frequency:50Hz;

5. Rated Current:800,1000A;

6. Limit Break Current:9KA;

7. Short circuit protection action time:<100ms;

8. Electrical life :3000 times;

9. Mechanical life :15000 times;

10. Circuit breaker contact technical parameters:

11. Open contact distance:3±0.5 mm;

12. Overstroke:  1.5±0.5 mm;

Related Products
Explosion Proof Vacuum Feed Switch
Mine Use Explosion Proof Vacuum Feed Switch
Application: Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to800, 1000A three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
Explosion Proof Intrinsically Safe Feed Switch Price
Mine Use Explosion Proof Intrinsically Safe Feed Switch
Application: Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to800, 1000A three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
Mine Explosion-Proof Equipment
Coal Mine Explosion-Proof and Intrinsically Safe Vacuum Feeder Switch
KJZ-500,630/1140(660) Mining explosion-proof and intrinsically safe vacuum feeder switch.Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to 500A(630A) three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
Mining Explosion-Proof Equipment
Mining Explosion-Proof and Intrinsically Safe Vacuum Feeder Switch
 Mining explosion-proof and intrinsically safe vacuum feeder switch.Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to 500A(630A) three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
Intrinsically Safe Vacuum Feed Switch
Mine Use Intrinsically Safe Vacuum Feed Switch For Coal Mining
Application: Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to800, 1000A three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
Frequency Converter on The Ground
BPG series AC inverter cabinet
BPG Series AC Converter Cabinet is a series of converters developed and designed by our company for non-explosion-proof applications on the ground. It is a high-tech product that integrates digital frequency conversion speed regulation device, high and low voltage distribution device, heat dissipation technology, digital display communication technology and moisture-proof and cold-proof technology.
Permanent Magnet Electric Motor
Explosion proof Permanent magnet motor
The permanent magnet synchronous motor adopts centralized winding, optimal pole slot coordination, and rotor structure integrating isolation, stress, positioning and lightweight, with small rotational inertia, small leakage flux, large main flux, higher power factor and higher efficiency. 
Dust suppressor
KJS series mine pneumatic wet dust suppressor
KJS series mine pneumatic wet dust precipitator is designed to be suitable for dust removal in gas discharge drilling holes, Tunnel Shotcreting, tunnel driving, etc. the dust precipitator is placed next to the drilling machine and shotcreting mixer, the roadheader body, the second transport belt, or the place designated by Party A, and the underground high-pressure water pipe is connected to the filter inlet. The filter outlet is connected to the inlet joint of the dust precipitator through the high-pressure rubber pipe, and the compressed air is connected to the air inlet. Open the high-pressure water valve and air pressure valve for operation.
We are committed to providing safe, energy-saving, efficient products and system solutions for intelligent mines.

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

whatsapp