other
Products

Mine flameproof and intrinsically safe reversible vacuum AC soft starter

This soft starter is suitable for coal mines containing explosive gas (methane) and coal dust. In AC 50Hz, voltage 1140V or 660V, neutral point ungrounded power supply system, perform various forms of soft starting (such as current limit, voltage ramp and power torque ramp for three-phase squirrel cage motors with currents below 200A and 400A) ) . It also has perfect protection function and fault display function, which greatly reduces the troubleshooting time.
  • Brand:

    WANTAI
  • Item NO.:

    QJR-400/1140(660)N
  • Goods Stock:

    1

Application

QJR-200, 400/1140(660)N mine flameproof and intrinsically safe reversible vacuum AC soft starter (hereinafter referred to as soft starter) is a new generation of high-tech products developed and produced by the latest technology of BENSHAW. , and its control units are all original Benxiu products. It adopts advanced microprocessor and power electronic control technology, realizes the soft start of AC motor, eliminates mechanical and electrical shock to the greatest extent, and prolongs the service life of the equipment. It is an ideal update for hydraulic coupling and other motor starting equipment. Replacement product. It has the characteristics of advanced technology, safe and reliable work, convenient maintenance, large starting torque and long service life, and its technical performance has reached the international advanced level.

Features
English LCD display.
Online protection monitoring.
Programmable low speed jog control.
The parameter panel is adjustable.
Dual parameter control function.
RS485 serial communication function.

Explosion-proof type: mine explosion-proof and intrinsically safe

Explosion-proof mark: Exd[ib] I Mb

Specifications

Rated working voltage: AC 1140V, 660V.
Rated working current: (400A) 1A~400A, (200A) 1A~200A, the current setting step is 1A.
The maximum power of the motor controlled when the rated voltage is 1140V and η*cosφ=0.75: (400A) 590kW; (200A) 296kW.
The maximum power of the motor controlled when the rated voltage is 660V and η*cosφ=0.75: (400A) 340kW; (200A) 171kW.
Control loop voltage: DC12V.
Maximum current overload multiple during soft start: adjustable below 8 times.
 Rated frequency: 50Hz.
Soft start time: 1~60s; (Because the thyristor inside the soft starter is cooled naturally, the soft start time is generally set between 6~15s, so as to avoid the damage of the thyristor caused by heating for a long time!).
Starting interval times: no more than 12 times per hour.
Kick start pulse time: 0~10s.
 Kick start pulse current: 100~800%.
Current limit: 0.5~8Ie.
Starting voltage: 0~100%Ue.
Cooling method: natural cooling.
 Communication method: RS485 serial communication.
Intrinsically safe parameters: U0: AC22V/DC12V; I0: 80mA/30mA.


Related Products
Mine explosionproof vacuum soft starter
Mine explosionproof and intrinsically safe low-voltage AC vacuum soft starter
Mining explosion-proof and intrinsically safe low voltage AC soft starter (hereinafter referred to as starter) is suitable for mine containing explosive dangerous gas and coal dust. in AC 50Hz, rated voltage AC1140V (660V) power supply system, four three-phase squirrel cage motors with current below 400A can be started in many forms (such as current limiting, voltage slope and power torque slope).
Mine soft starter
Mining explosion-proof and intrinsically safe vacuum soft starter
The soft starter is suitable for coal mines containing explosive gas (methane) and coal dust.In an AC 50Hz, voltage 1140V or 660V, neutral ungrounded power supply system, various forms of soft start (such as current clipping, voltage ramp and power torque ramp) are performed on three-phase squirrel-cage motors with currents up to 200A and 400A.The controller also has the perfect protection function and the fault display function, greatly reduces the time of troubleshooting.
high voltage vacuum soft starter
Mine flameproof and intrinsically safe high voltage vacuum soft starter
High-voltage soft starter is suitable for mines containing explosive gas (methane) and coal dust. In the AC 50Hz voltage of 10kV or 6kV lines, the control methods can be local control, remote control, network control and other control methods, used for high-power motors soft start and soft stop.
high voltage vacuum soft starter
Mining high voltage vacuum soft starter
High-voltage soft starter is suitable for mines containing explosive gas (methane) and coal dust. In the AC 50Hz voltage of 10kV or 6kV lines, the control methods can be local control, remote control, network control and other control methods, used for high-power motors soft start and soft stop.
Permanent Magnet Electric Motor
Mine flameproof and intrinsically safe deceleration permanent magnet synchronous frequency conversion speed regulating integrated machine
Taking advantage of the low-speed and high torque of permanent magnet motor, combined with the torque amplification function of planetary reducer and the control of frequency converter, the low-speed drive all-in-one machine has the smallest volume and the best performance. It is suitable for installation space limited and movable equipment.
Mining tension sensor
Coal Mine Use Smoke/Temperature/Tension Sensor
Application: GAD5 (B) mine intrinsically safe tension sensor is used in workplaces such as underground coal mines, open-pit coal mines, and coal preparation plants. It is used to detect the tension protection signal of the integrated protection device of the belt conveyor.
Mine Dust Fan
FQ Series Mining Pneumatic Press in Axial Flow Local Fan
The working time of underground coal bunker, water bunker, equipment chamber and other works in the coal mine is short. If the electric fan is used to connect the power and arrange the fan, it is very troublesome, time-consuming and labor-consuming. According to this situation, the company has developed FQ series mine pneumatic press in axial flow local fan, which is suitable for short-distance air supply during coal bunker, water bunker maintenance and roadway excavation.
Starter
Mine Explosion-proof Starter
This product is suitable for an environment with coal mine gas, coal dust, and other explosive gases underground, to logically control the start, stop and double-speed of the three-phase AC asynchronous motor or AC double-winding motor in the circuit of AV 1140V or 660V. And it has a joint control function.
We are committed to providing safe, energy-saving, efficient products and system solutions for intelligent mines.

Leave A Message